Cable cells#

Warning

The interface for building and modifying cable cell objects has changed significantly; some of the documentation below is out of date.

The C++ cable cell documentation should have the same structure as the Python cable cell documentation.

Cable cells, which use the cell_kind cable, represent morphologically-detailed neurons as 1-d trees, with electrical and biophysical properties mapped onto those trees.

A single cell is represented by an object of type cable_cell. Properties shared by all cable cells, as returned by the recipe get_global_properties method, are described by an object of type cable_cell_global_properties.

The cable_cell object#

Cable cells are constructed from a morphology; an optional label_dict that associates names with particular points (locset objects) or subsets (region objects) of the morphology; and an optional decor.

Morphologies are constructed from a segment_tree, but can also be generated via the stitch_builder, which offers a slightly higher level interface. Details are described in The stitch-builder interface.

Each cell has particular values for its electrical and ionic properties. These are determined first by the set of global defaults, then the defaults associated with the cell, and finally by any values specified explicitly for a given subsection of the morphology via the paint interface of the decor (see Electrical properties and ion values and Overriding properties locally).

Ion channels and other distributed dynamical processes are also specified on the cell via the paint method; while synapses, current clamps, gap junction mechanisms, and the site for testing the threshold potential are specified via the place method. See Cell dynamics, below.

Cell dynamics#

Dynamics are imbued onto the cell by setting a decor object during construction. Each segment in a cell may have attached to it one or more density mechanisms, which describe biophysical processes. These are processes that are distributed in space, but whose behaviour is defined purely by the state of the cell and the process at any given point.

Cells may also have point mechanisms, describing the dynamics at post-synaptic sites. And junction mechanisms, describing the dynamics at each site of the two sites of a gap-junction connection.

A fourth type of mechanism, which describes ionic reversal potential behaviour, can be specified for cells or the whole model via cell parameter settings, described below.

Mechanisms are described by a mechanism_desc object. These specify the name of the mechanism (used to find the mechanism in the mechanism catalogue) and parameter values for the mechanism that apply within a segment. A mechanism_desc is effectively a wrapper around a name and a dictionary of parameter/value settings.

Mechanism descriptions can be constructed implicitly from the mechanism name, and mechanism parameter values then set with the set method. Relevant mechanism_desc methods:

mechanism_desc::mechanism_desc(std::string name)#

Construct a mechanism description for the mechanism named name.

mechanism_desc &mechanism_desc::set(const std::string &key, double value)#

Sets the parameter associated with key in the description. Returns a reference to the mechanism description, so that calls to set can be chained in a single expression.

density, synapse and junction objects are thin wrappers around a mechanism_desc, needed for painting and placing mechanisms on a decor. Relevant methods:

density::density(mechanism_desc mech)#

Construct a density wrapper from the mechanism mech.

density::density(mechanism_desc mech, const std::unordered_map<std::string, double> &params)#

For each {key, value} pair in params, set the parameter associated with key to value on mechanism mech, then construct a density wrapper from the mechanism mech.

synapse::synapse(mechanism_desc mech)#

Construct a synapse wrapper from the mechanism mech.

synapse::synapse(mechanism_desc mech, const std::unordered_map<std::string, double> &params)#

For each {key, value} pair in params, set the parameter associated with key to value on mechanism mech, then construct a synapse wrapper from the mechanism mech.

junction::junction(mechanism_desc mech)#

Construct a junction wrapper from the mechanism mech.

junction::junction(mechanism_desc mech, const std::unordered_map<std::string, double> &params)#

For each {key, value} pair in params, set the parameter associated with key to value on mechanism mech, then construct a junction wrapper from the mechanism mech.

Density mechanisms are associated with a cable cell object with:

void decor::paint(const region&, density)#

Point mechanisms, which are associated with connection end points on a cable cell, are placed on a set of locations given by a locset. The group of generated items are given a label which can be used to create connections in the recipe. Point mechanisms are attached to a cell with:

void decor::place(const locset&, synapse, cell_tag_type label)#

Gap-junction mechanisms, which are associated with gap-junction connection end points on a cable cell, are placed on a single location given by a locset (locsets with multiple locations will raise an exception). The generated item is given a label which can be used to create gap-junction connections in the recipe. Gap-junction mechanisms are attached to a cell with:

void decor::place(const locset&, junction, cell_tag_type label)#

Todo

TODO: describe other place-able things: current clamps, threshold potential measurement point.

Electrical properties and ion values#

On each cell segment, electrical and ion properties can be specified by the parameters field, of type cable_cell_local_parameter_set.

The cable_cell_local_parameter_set has the following members, where an empty optional value or missing map key indicates that the corresponding value should be taken from the cell or global parameter set.

class cable_cell_local_parameter_set#
std::unordered_map<std::string, cable_cell_ion_data> ion_data#

The keys of this map are names of ions, whose parameters will be locally overridden. The struct cable_cell_ion_data has three fields: init_int_concentration, init_ext_concentration, and init_reversal_potential.

Internal and external concentrations are given in millimolars, i.e. mol/m³. Reversal potential is given in millivolts.

util::optional<units::quantity> init_membrane_potential#

Initial membrane potential in millivolts.

util::optional<units::quantity> temperature#

Local temperature in Kelvin.

util::optional<units::quantity> axial_resistivity#

Local resistivity of the intracellular medium, in ohm-centimetres.

util::optional<units::quantity> membrane_capacitance#

Local areal capacitance of the cell membrane, in Farads per square metre.

util::optional<cv_policy> discretisation#

Method by which CV boundaries are determined when the cell is discretised. See Discretisation and CV policies.

Default parameters for a cell are given by the default_parameters field in the cable_cell object. This is a value of type cable_cell_parameter_set, which extends cable_cell_local_parameter_set by adding an additional field describing reversal potential computation:

class cable_cell_parameter_set : public cable_cell_local_parameter_set#
std::unordered_map<std::string, mechanism_desc> reversal_potential_method#

Maps the name of an ion to a ‘reversal potential’ mechanism that describes how it should be computed. When no mechanism is provided for an ionic reversal potential, the reversal potential will be kept at its initial value.

Default parameters for all cells are supplied in the cable_cell_global_properties struct.

Global properties#

class cable_cell_global_properties#
const mechanism_catalogue *catalogue#

all mechanism names refer to mechanism instances in this mechanism catalogue. by default, this is set to point to global_default_catalogue(), the catalogue that contains all mechanisms bundled with arbor.

optional<double> membrane_voltage_limit_mv#

if set, check to see if the membrane voltage ever exceeds this value in magnitude during the course of a simulation. if so, throw an exception and abort the simulation.

bool coalesce_synapses#

when synapse dynamics are sufficiently simple, the states of synapses within the same discretised element can be combined for better performance. this is true by default.

std::unordered_map<std::string, int> ion_species#

every ion species used by cable cells in the simulation must have an entry in this map, which takes an ion name to its charge, expressed as a multiple of the elementary charge. by default, it is set to include sodium “na” with charge 1, calcium “ca” with charge 2, and potassium “k” with charge 1.

cable_cell_parameter_set default_parameters#

the default electrical and physical properties associated with each cable cell, unless overridden locally. in the global properties, every optional field must be given a value, and every ion must have its default values set in default_parameters.ion_data.

add_ion(const std::string &ion_name, int charge, double init_iconc, double init_econc, double init_revpot)#

convenience function for adding a new ion to the global ion_species table, and setting up its default values in the ion_data table.

add_ion(const std::string &ion_name, int charge, double init_iconc, double init_econc, mechanism_desc revpot_mechanism)#

As above, but set the initial reversal potential to zero, and use the given mechanism for reversal potential calculation.

For convenience, neuron_parameter_defaults is a predefined cable_cell_local_parameter_set value that holds values that correspond to NEURON defaults. To use these values, assign them to the default_parameters field of the global properties object returned in the recipe.

Reversal potential dynamics#

If no reversal potential mechanism is specified for an ion species, the initial reversal potential values are maintained for the course of a simulation. Otherwise, a provided mechanism does the work, but it subject to some strict restrictions. A reversal potential mechanism described in NMODL:

  • May not maintain any STATE variables.

  • Can only write to the “eX” value associated with an ion.

  • Can not be given as a POINT mechanism.

Essentially, reversal potential mechanisms must be pure functions of cellular and ionic state.

If a reversal potential mechanism writes to multiple ions, then if the mechanism is given for one of the ions in the global or per-cell parameters, it must be given for all of them.

Arbor’s default catalogue includes a “nernst” reversal potential, which is parameterized over a single ion, and so can be assigned to e.g. calcium in the global parameters via

cable_cell_global_properties gprop;
// ...
gprop.default_parameters.reversal_potential_method["ca"] = "nernst/ca";

This mechanism has global scalar parameters for the gas constant R and Faraday constant F, corresponding to the exact values given by the 2019 redefinition of the SI base units. These values can be changed in a derived mechanism in order to use, for example, older values of these physical constants.

mechanism_catalogue mycat(global_default_catalogue());
mycat.derive("nernst1998", "nernst", {{"R", 8.314472}, {"F", 96485.3415}});

gprop.catalogue = &mycat;
gprop.default_parameters.reversal_potential_method["ca"] = "nernst1998/ca";

Overriding properties locally#

Todo